4 permits on latest day valuation that day2,363,807 permits on recordLast sync Jul 05, 11:15 PM CTOfficial permit records · verified daily
MAP / ZIP 78754 / 2026-075947 EP
PERMIT 2026-075947 EP

1506 BRUSHY VIEW CV

Active
Electrical PermitRepairResidential

Scope of work

Installation of: OFF-GRID PV + Battery System System Size: SOLAR PV: 7.2 kW-DC/11.4 kW-AC BATTERY: 15kWh Modules: 16 CW ENERGY: CWT450-108TNB10 - 450W Inverter(s): 1 FRANKLIN WH INVERTER BATTERY: APOWER S-10 APRS-10K15V1-US Other: 1 FRANKLIN WH MID: AGATE X 1 FRANKLIN WH INVERTER BATTERY: APOWER S-10 APRS-10K15V1-US 1 MAIN SERVICE PANEL: 125A 1 MLO PANEL: 125A 1 EV CHARGING RECEPTACLE: 120V NEMA 14-50 Notes: OFF-GRID System: NOT interconnecting with Austin Energy grid PV array inverter battery aGate main service panel & EV charger to be located on existing carport. TRENCH: APPROXIMATELY 65 ft - AT LEAST 18 DEPTH ABOVE CONDUIT PER NEC 300.5 MLO panel to be located inside workshop

Record

Permit number2026-075947 EP
StatusActive
Applied06-15-26
Issued06-18-26
Expires12-15-26
Completed
Valuation
Housing units1
Council district1
Official recordCity of Austin →

Contractor

Prometheus Power Solutions
Electrical Contractor
Phone•••••••••••PRO
Full permit history →

This property

6 permits on record at this address.

Full property history →

⚡ Alerts for work like this

Every new Electrical Permit permit in 78754, in your inbox the morning it’s issued.

Set alert · Pro