PERMIT 2016-058813 PP
4001 HARBORLIGHT CV
Final
Plumbing PermitRepairResidential
Scope of work
Install RPZ (Reduced Pressure Zone backflow preventer) at meter. To allow for thermal expansion install expansion tank or other approved device (pressure relief valve set @ 100lbs (house side)) test RPZ and perform CCT label per DSD (Purple pipe purple box lids hose bibs labeled non-potable if tied to auxiliary water source) check all boxes that apply. If city backup is to be used for irrigation another RPZ must be installed and tested. If not the existing backflow preventer must be removed and the lines capped.
Record
Permit number2016-058813 PP
StatusFinal
Applied05-19-16
Issued05-19-16
Expires05-23-16
Completed05-23-16
Valuation—
Housing units1
Council district10
Official recordCity of Austin →