282 permits on latest day$814k valuation that day2,386,174 permits on recordLast sync Nov 19, 11:45 AM CTOfficial permit records · verified daily
Map/Zip 78722/2025-137956 BP

2204 ALEXANDER AVE BLDG 2

Active
Building PermitNewResidential

Scope of work

BUILDING 2 1 STORY SFR 2/1 REAR OF MAIN HOUSE Revision: Permit Revision Narrative: This resubmittal documents three major revisions to the approved permit drawings for this residential development. 1. Conditioned Square Footage Unit 1: The total conditioned square footage for Unit 1 increased to include an enclosed dining room. The screened porch from the previous design is no longer part of the project scope. There are no other permit relevant revisions to Unit 1. Unit 2: The floor plan layout of Unit 2 has been revised. Floor plan on A1.2 show updated visitable route and bathroom smoke/carbon monoxide detector locations attic access and call out square footage and ceiling heights by space. Escape and rescue openings are called out in the window and door schedules on sheet A1.3. Shared Accessory Room: Introduced a new shared accessory room between Unit 1 & Unit 2. Updated FAR calculations are provided on A0.1. 2. Building Footprint & Envelope The proposed revision required minor adjustments to the building footprint & foundation. As part of the revised design the footprint of the wood deck also adjusted. Updated impervious cover and total building coverage calculations are provided on A0.1. Revisions to openings and new openings are shown in the updated window and door schedules on sheet A1.3. 3. Fire Separation Between Dwelling Units The revised design locates a shared accessory room per 2024 IRC R302.3.6 between Unit 1 and Unit 2. The function of the shared accessory room is to provide a storage space accessible from both units. The walls between the shared accessory room and dwelling units are separated per Table R302.3.6 Dwelling Shared Accessory Room Separation and separation requirements are vertically continuous from foundation to roof deck. Structures supporting the ceiling of the shared accessory room are separated per Table R302.3.6 Dwelling Shared Accessory Room Separation. There is no habitable space above or below the shared accessory room. All openings in walls separating dwelling units from the shared accessory room are compliant with R302.3.6.1 Opening Protection. All duct penetrations shall comply with R302.3.6.2 and shall not have openings into the shared accessory room. All other penetrations shall comply with R302.3.6.3. See A0.2 Fire Separation & Details for updated code compliance diagrams.

Record

Permit number2025-137956 BP
StatusActive
Applied07-11-25
Issued10-12-26
Expires04-13-27
Completed-
Valuation-
New / added sqft644
Housing units2
Council district1
Official recordCity of Austin →

Contractor

A.R. Lucas Construction LLC
General Contractor
Phone•••••••••••PRO
Full permit history →
⚡ Alerts for work like this

Every new Building Permit permit in 78722, in your inbox the morning it’s issued.

Set alert · Pro